Performance advantages of Small SIZE Reflow Oven
Â
â— Customizable Split Type: No lifting or wall dismantling required.
â— Equipped with Built-In Three-Channel Furnace Temperature Testing Program and Real-Time Temperature Curves.
â— High Precision Transmission Support Structure with durable guide rail chain.
â— Precision Maintenance Design for quick disassembly and installation.
â— Unique Cooling Zone Structure reduces cleaning frequency and filters flux.
â— Efficient Emission Filtration Device to meet workshop requirements.
â— Microcirculatory Hot Air Management System for efficient convective conduction and fast thermal compensation.
â— Fully Compatible with Various Welding Process Requirements.
Â
Specific models of Small Size Reflow Oven
Â
Model | HX-320AF | HX-420AF | HX-520AF | HX-620AF |
Dimensions(LxWxH)mm | 2000x650x1260 | 2500x650x1260 | 3000x650x1260 | 3500x650x1260 |
Color | ivory white | |||
Weight(mm) | Approx 240 | Approx 300kg | Approx 350kg | Anprox 550KR |
Heating zones | Up 3/Bottom 2 | Up 4/Bottom 4 | Up 5/FBottom 5 | Up 6/Bottom 6 |
Heating zones length | 1000mm | 1400mm | 1750mm | 2100mm |
Cooling zones | 1 zone (top and bottom) | |||
Heating structure | Microcirculation structure | |||
Pumping wind | 15m³/min 2 passageway |
Â
Control System | Â | |||
Power | 3 phase 5 wire system 380V 50/60Hz(customizable) | |||
Total power | 10Kw | 16Kw | 22Kw | 27Kw |
Starting power | 10Kw | 16Kw | 22Kw | 27KW |
Normal power | 3Kw | 5Kw | 7Kw | 9Kw |
Heating time | Apporx 15min | |||
Temp range | Room Temp -320°C | |||
Temp control method | Thermostat PID closed loop control +SSR drive | |||
Temp accuracy | ±2℃ | |||
Lateral temp deviation | ±2℃ | |||
Par ameterstor age | Can store and retrieve a variety of process parameters and furnace temp graph | |||
Abnormal alarm | Abnormal temp,communication error,hardware alarm | |||
Remote control | 0ptional |
Â
Transportation System | Â |
Wesh belt structure | Stainless steel monolithic |
Transmission structure | High temperature gear transmission,round shaft and bearing support |
Max width | Mesh belt 300mm or 350mm Can withstand 30Kg(Customizable) |
Ninimum widtt | Infinitesimal |
Inner height | 30mm |
Transportation directio | left+right(Optional:Right+left) |
Transportation method | mesh belt |
Working height | 900±20mm (customizable) |
Transport belt speed | 100-2000mm/min (customizable) |
Lubricating oil | Automatic or manual |
Â
Cooling system | Â |
Cooling method | High temperature resistant fan forced normal air cooling |
0ption | Â |
Full hot air system | Can be equipped with up and down full hot air heating |
Computer control | Equipped with Mitsubishi PLC and Dell display,industrial control |
Â
http://www.hxcnsmt.com/